82 research outputs found

    Consideration of Tool Chamfer for Realistic Application of the Incremental Hole-Drilling Method

    Get PDF

    Correlation of Microstructure and Properties of Cold Gas Sprayed INCONEL 718 Coatings

    Get PDF
    In the cold gas spray process, deposition of particles takes place through intensive plastic deformation upon impact in a solid state at temperatures well below their melting point. The high particle impact velocities and corresponding peening effects can lead to high compressive residual stresses in cold spray coatings. This can be advantageous with regard to mechanical properties as fatigue life and hence, cold spray is an ideal process for repair applications. In this study, INCONEL 718 particles were cold sprayed by using nitrogen as propellant gas. The deposited coatings with different thicknesses were characterized using electron microscopy techniques to study grain refinement and precipitates in the coating. In addition, depth-resolved residual stress measurements have been performed by the incremental hole drilling method. The residual stress depth profiles in the coatings indicate compressive residual stresses of several hundred MPa which are hardly influenced by the coating thickness. In addition, large compressive stress levels are found in surface- near regions of the substrate due to the grit blasting process. Furthermore, a post-heat treatment analysis was performed to investigate its influence on residual stresses and bonding strength. These findings are used to develop a consistent explanation of the dependence of strength values on thickness

    Short-term heat treatment of ti6al4v eli as implant material

    Get PDF
    Due to its mechanical properties and good biocompatibility, Ti6Al4V ELI (extra low interstitials) is widely used in medical technology, especially as material for implants. The specific microstructures that are approved for this purpose are listed in the standard ISO 20160:2006. Inductive short-term heat treatment is suitable for the adjustment of near-surface component properties such as residual stress conditions. A systematic evaluation of the Ti6Al4V microstructures resulting from short-term heat treatment is presently missing. In order to assess the parameter field that leads to suitable microstructures for load-bearing implants, dilatometer experiments have been conducted. For this purpose, dilatometer experiments with heating rates up to 1000 °C/s, holding times between 0.5 and 30 s and cooling rates of 100 and 1000 °C/s were systematically examined in the present study. Temperatures up to 950 °C and a holding time of 0.5 s led to microstructures, which are approved for medical applications according to the standard ISO 20160:2006. Below 950 °C, longer holding times can also be selected

    Numerical characterization of residual stresses in a four-point-bending experiment of textured duplex stainless steel

    Get PDF
    The resulting shapes in production processes of metal components are strongly influenced by deformation induced residual stresses. Dual-phase steels are commonly used for industrial application of, e.g., forged or deep-drawn structural parts. This is due to their ability to handle high plastic deformations, while retaining desired stiffness for the products. In order to influence the resulting shape as well as component characteristics positively it is important to predict the distribution of phase-specific residual stresses which occur on the microscale of the material. In this contribution a comparative study is presented, where two approaches for the numerical simulation of residual stresses are applied. On the one hand a numerically efficient mean field theory is used to estimate on the grain level the total strain, the plastic strains and the eigenstrains based on macroscopic stress, strain and stiffness data. An alternative ansatz relies on a Taylor approximation for the grain level strains. Both approaches are applied to the corrosion-resistant duplex steel X2CrNiMoN22-5-3 (1.4462), which consists of a ferritic and an austenitic phase with the same volume fraction. Mean field and Taylor approximation strategies are implemented for usage in three dimensional solid finite element analysis and a geometrically exact Euler–Bernoulli beam for the simulation of a four-point-bending test. The predicted residual stresses are compared to experimental data from bending experiments for the phase-specific residual stresses/strains which have been determined by neutron diffraction over the bending height of the specimen

    Neutronographic Residual Stress Analysis for Materials With Depth Gradients of the Strain Free Lattice Parameter d0{{{d}}}_{0} for the Example of a Case-Hardened Steel 20MnCr5

    Get PDF
    In the present work, ring-shaped samples made from steel 20MnCr5 were low-pressure carburized (LPC) and subsequently hardened by gas quenching (case-hardened). This results in a near-surface gradient in chemical composition, microstructure- and hardness distribution, as well as a three-dimensional residual stress (RS) distribution, which was investigated by neutron diffraction. Near-surface RSs in the ferrite-/martensite- and austenite phase are additionally determined by X-ray diffraction. It is shown that the chemical gradient has an influence on the chosen d0{{{d}}}_{0} strategy and how such a reference sample should be extracted. If near-surface RS values are to be determined by neutron diffraction, the pseudo-strain effect must be taken into account. For this purpose, a suitable approach using the ‘‘open source’’ software SIMRES and STRESSFIT is also presented. By combining neutron and X-ray diffraction data, a complete RS distribution over the whole sample can be obtained

    Fast Temporal and Spatial Resolved Stress Analysis at Laser Surface Line Hardening of Steel AISI 4140

    Get PDF
    Local and temporal strain and stress evolution is recorded by synchrotron X-ray diffraction during laser line hardening of SAE 4140 steel in the quenched and tempered states at different measuring positions with respect to the process zone. The in-situ diffraction experiments were performed at beamline P05@Petra III at DESY, Hamburg (Germany). The steel samples were line hardened using a 4 kW high-power diode laser (HPDL) unit at a constant laser feed of 800 mm/min. Using a specially designed process chamber that incorporates symmetrically attached fast silicon micro-strip line detectors, stress analysis using the sin²ψ-method in single-exposure mode, enabled measuring rates at 20 Hz. As a result of the temporal and spatial resolved analyses, the elastic strains were separated from the thermal strains

    Effects of finish turning on an austenitic weld investigated using diffraction methods

    Get PDF
    Arc welding generally introduces undesired local residual stress states on engineering components hindering high-quality performance in service. Common procedures to reduce the tensile residual stresses are post-heat treatments or mechanical surface treatments like hammering or shot-peening. Assessments of residual stress profiles of post-weld treatments underneath the weld surface are essential, especially in high safety exigency systems like pressure vessels or piping at power plants. In this study, neutron diffraction is used to determine the stress profile after finish milling of an austenitic steel weld in order to verify a chained finite element simulation predicting the final residual stress fields including milling and welding contributions. Non-destructive measurements with spatial resolutions of less than 0.2 mm within the first 1 mm from the surface were mandatory to confirm the finite element simulations of the coarse-grained austenitic material. In the data analysis procedure, the obtained near-surface data have been corrected for spurious strain effects whenever the gauge volume was partially immersed in the sample. Moreover, constraining the surface data to values obtained by x-ray diffraction and data deconvolution within the gauge volume enabled access of the steep residual stress profile within the first 1 mm

    Corrosion Behavior of Surface-Treated Metallic Implant Materials

    Get PDF
    Corrosion of taper connections in total hip arthroplasty remains of concern, as particles and ions generated by corrosive processes can cause clinical problems such as periprosthetic osteolysis or adverse reaction to metallic debris. Mechanical surface treatments that introduce compressive residual stresses (RSs) in metallic materials can lead to a better performance in terms of fretting and fatigue and may lower the susceptibility to corrosion. The study investigates the impact of mechanical surface treatments on the corrosion behavior of metallic biomaterials. Compressive RSs were introduced by deep rolling and microblasting in Ti6Al4V and CoCrMo samples. Polished samples served as reference. Corrosion behavior was characterized by repeated anodic polarization. Residual stresses of up to about −900 MPa were introduced by deep rolling with a reach in depth of approximately 500 µm. Microblasting led to compressive RSs up to approximately −800 and −600 MPa for Ti6Al4V and CoCrMo, respectively, in the immediate vicinity of the surface. For Ti6Al4V, microblasting resulted in decreased corrosion resistance with lower breakdown potentials and/or increased passive current densities in comparison to the polished and deep-rolled samples. The corrosion behavior of CoCrMo on the other hand was not affected by the mechanical surface treatments
    • …
    corecore